Power Demand Analyzer (Custom 500A Kit)
The 3169-20 and 3169-21 are CLAMP ON POWER HiTESTERs that allow measurement of single-phase to three-phase 4-wire circuits with a single unit. In addition to measuring standard parameters such as voltage, current, power, power factor, and integrated values, these clamp-on power meters can simultaneously perform demand measurements required for carrying out power management and energy-saving measures, as well as harmonic measurements. The two new power meters also feature PC card data storage, and come equipped with an RS-232C interface for PC communications. Further, with greater data processing speeds, it is possible to measure the power of just a few cycles, enabling more detailed and effective energy-saving measures for equipment. The 3169-20 and 3169-21 are ideal for users who want to achieve close control over energy-saving management activities and measures.
The 3169-20/21 can simultaneously measure voltage, current, power (active, reactive, and apparent), integrated power, power factor, and frequency. Further, when using 3-phase, 3-wire (3P3W2M) mode, you can display the voltage and current for all three lines by measuring just two of them. When using the 3-phase, 4-wire (3P4W4I) mode, neutral line current can be displayed using 4 current measurement.
The power meters come equipped with a harmonics measurement function that supports measurement of 3-phase power lines. They can also perform simultaneous measurement of harmonics and demand values, enabling both power and harmonics management.
Applications
Energy Maintenance / Control
Energy Control Under ISO 14000
Saving Energy Activities
Power Consumption Measurement of Specific Device / Equipment
Harmonic Analysis
In The Box
Clamp On Sensors 9661 (AC 500A) x4
Voltage cord L9438-53 ×1
Alligator clip ×4
Power cord ×1
Instruction manual ×1
Quick start manual ×1
CD-R ×1
RS-232C interface operating manual ×1
Input cord label ×1
Manuals/Guides
Brochures
Catalog 2
Manuals
Cross Reference
Product Manual
Spec Sheets
Datasheet
Other
Catalog 2
Manufacturer Specs
Measurement Line Type: Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, and three-phase 4-wire systems (50/60 Hz)
Number of Systems That Can be Measured: Single-phase: 1P2W 4 systems, 1P3W 2 systems
Three-phase: 3P3W2M (measures the voltage and current for two lines) 2 systems, 3P3W3M (measures the voltage and current for all three lines) 1 system, 3P4W (measures the voltage and current for three lines) 1 system, 3P4W4I (measures the voltage for three lines and the current for four lines) 1 system
Measurement Item: Voltage, current, active power, reactive power, apparent power, power factor, integrated value, frequency, harmonics
Measurement Range: Voltage: 150 V to 600 V, 3 ranges
Current (When using 9660): 5 A to 100 A, 4 ranges
Current (When using 9661): 5 A to 500 A, 5 ranges
Current (When using 9669): 100 A to 1 kA, 3 ranges
Current (When using 9667): 500 A / 5 kA, 2 ranges
Current (When using 9694): 0.5 A to 5 A, 3 ranges
Power: 75 W to 9 MW, 108 combination patterns
Basic Accuracy: ±0.2% rdg. ±0.1% f.s. + clamp-on sensor accuracy (active power, at 45 to 66 Hz)
Clamp Sensor Accuracy: 9660 (rated for 100 A): ±0.3% rdg. ± 0.02% f.s.
9661 (rated for 500 A): ±0.3% rdg. ±0.01% f.s.
9669 (rated for 1000 A): ±1.0% rdg. ±0.01% f.s.
9667 (rated for 5000 A): ±2.0% rdg. ±1.5 mV
9694 (rated for 5 A): ±0.3% rdg. ±0.02% f.s.
* f.s. is the sensor’s rated primary current value.
Frequency Characteristics: Fundamental waveforms up to the 50th order ±3% f.s. + measurement accuracy (of a 45- to 66-Hz fundamental waveform)
Other Functions: PC card (1 slot, PC Card Standerd-compliant Type II, Flash ATA card type)
RS-232C (Printer or PC connected to an RS-232C interface)
External I/O
Display Update Rate: Approx. every 0.5 seconds
(except when using a PC card while accessing the internal memory, or when performing RS-232C communications)
Power Supply: 100 to 240 V AC, 50/60 Hz
Dimensions: 210mm W × 160mm H × 60mm D ±5 mm (excluding protrusions)
Weight: 1.2 kg ±100 g
Accessories: 9438-03 voltage cord set (1) (1 cord each of black, red, yellow, and blue), voltage cord (1), power cord (1), input cord label (1), operating manuals (2) (Advanced edition and Quick Start Guide), CD-R (1) (Advanced edition and RS-232C interface operating manuals)
Tech Specs
Power Measurement/Power Loggers Template
Input(power loggers) Single Phase, Three Phase
Type(Power loggers) Analog, Digital, Portable Hand Held
Maximum Current AC 500 A
Maximum Voltage AC 600 V
True RMS Yes
Power Quality No
Current Input Channels 4
Voltage Input Channels 4
Measurement Frequency 50 Hz, 60 Hz
Display (Energy Management) Analog, Digital, Graphical
Transient Capture No
Displays Waveform No
Energy Yes
Phasor Diagrams Yes
Power Factor (Power Quality) Yes
Harmonics Yes
Total Harmonic Distortion Yes
Current Clamps Included Yes
Test Equipment General Attributes
Storage Compact Flash
Product Weight 1.2 KILOS (2.65 LBS)
Product Height 60 IN
Product Length 210 IN
Product Width 160 IN
HTS/Schedule B Number 9030.33.3400
ECCN Number 3A992
Power Supply Voltage 120V 50/60 Hz
Country of Origin Japan
Shipping Height 7.10 IN
Shipping Length 19.00 IN
Shipping Width 13.80 IN